Sensor Circuit Solutions:
Outputs two 4-20mA current signals with output current limit protection
The excitation voltage of the strain gauge is 5V
Support strain gauge impedance 350~1k Ω
The signal amplification circuit uses a two-point calibration, and the calibrated parameters can be stored inside the device
It supports bidirectional tension pressure signal conditioning and amplification applications
It supports all-digital debugging and calibration, and is equipped with special test and calibration software
The unique anti-interference design makes the product have the characteristics of high reliability and long-term stability
The power supply voltage is DC 7V-36V, with anti-reverse polarity protection and over-voltage and over-current protection
The PCB size is 25*35*10mm rectangular, and special sizes or shapes are accepted
The working environment temperature is -20~85°C, the humidity is <85%, and the environment is dry and corrosive